HY0170 Series Fiber Fineness Analysis System consists of optical microscope, high resolution industrial camera and computer, to perform fiber diameter and cross-sectional area tests by using professional software. It also can determine the content of each fiber in the blended fiber. HY0170 series contains several different models since different microscope and different software.
HY0170
Anytester
Availability: | |
---|---|
Product Description
HY0170 Series Fiber Fineness Analysis System consists of optical microscope, high resolution industrial camera and computer, to perform fiber diameter and cross-sectional area tests by using professional software. It also can determine the content of each fiber in the blended fiber. HY0170 series contains several different models since different microscope and different software.
Standards
AATCC20/A-2011, | ISO137-1975, ISO 17751, , | IWTO-8-2004, IWTO-47-2009, |
TWC-TM24-2009 | SN/T 1062, 0756 | GB/T 20732-2006, 10685-2007, 16988 |
FZ/T 01057.3, 30003, 32004, 01101-2008 |
Features
HY0170A Fineness type
★ Qualitative analysis, conforms to AATCC20-2011, FZ/T01057.3
★ Used to determine the fiber diameter of animal fiber, chemical fiber, cotton and flax fiber, etc. Fast to test, easy to operate, with small human error
★ Fiber diameter measurement, conforms to ISO137-1975, IWTO-8-2004, TWC-TM24-2009, GB/T 10685-2007
★ With automatic test function of fiber diameter (optional), conforms to IWTO-47-2009, GB/T 20732-2006
★ Measuring range: 1~2000μm
★ Data and report output in EXCEL format, it also can be customized as customer’s requirement
HY0170B Content type
★ Contains all the functions of HY0170A
★ It can determine fiber content of various blended products by analyzing single fiber morphology and measuring diameter
★ It conforms to ISO 17751, SN/T 1062, GB/T 16988, SN/T 0756, FZ/T30003, FZ/T 32004, etc.
★ Adopts professional analysis software, data and report output in EXCEL format
★ Provided with sample gallery of special animal fiber, chemical fiber, cotton and flax fiber, convenient to contrast for operator, improve the ability of identification
HY0170C Integrated type
★ Contains all the functions of HY0170B
★ It can used to observe cross-sectional morphology of chemical fiber, profiled fiber and hollow fiber, and also can determine cross-sectional area
★ It conforms to AATCC 20A-2011, FZ/T 01101-2008
★ It also can determine shape factor and hollow degree, conforms to FZ/T 50002-1991
Technical Specification
Model | HY0170 |
Measuring range | 1~2000μm |
Objective lens | 4×, 10×, 20× |
System magnification | 25× |
Sample magnification | 100×, 250×, 500× |
Power supply | AC220V, 50Hz |
Weight | 25kg |